Offices, hallways and commercial interiors
In an office nobody thanks you for the savings. They notice the hum stopping and the glare going away.
Easiest retrofit to do cheaply, easiest one to get wrong. The measure of success is whether people stop complaining. These are the three complaints.
Commercial interiors and ceilings, shot on the day







Swipe. Interior ceiling work first. No office grid photo in here yet, and I am not going to borrow somebody else's.
5.0 on Google · 70+ verified reviews
What business customers say
Nobody has left us a review on a lighting retrofit yet, so I am not going to show you one. These two are real, from a business customer and a repeat electrical customer.
Swipe sideways for 1 more →
Where the watts actually go, office
4 lamp T8 troffer
110 to 132 W a fixture
Plus the ballast hum in a quiet room.
LED tube, ballast removed
60 W a fixture
Cheapest path that kills the hum.
New LED fixture, 4000 K
50 W a fixture
4000 K, not 5000 K. 5000 K is the complaint I get called back on.
One for one. I do not thin out an office grid to hit a number.
A troffer swap, drawn honestly
55 to 62%
less power a fixture
50 to 60 W against 110 to 132 W. In an office the hum going away is the thing people actually notice first.
The office spec
Four things that decide whether people like it
4000 K, and the same 4000 K everywhere
Warmer than a warehouse, and consistent. A hallway at 5000 K running into offices at 4000 K reads as one of them being broken. Pick it once, specify the same product for the fixtures you add later.
IES recommended light levels compilationGlare on screens is the actual complaint
Everybody in an office is looking at a lit screen under a lit ceiling. The wrong diffuser puts a reflection of your fixture in the middle of somebody spreadsheet all day. This is a fixture selection issue, not a wattage issue.
Ballast hum is why they called you
A quiet room and an aging magnetic ballast are a bad combination, and it gets worse every year. Removing the ballast removes the hum. Leaving it in on a Type A retrofit does not.
347 V changes the recommendation
Most Alberta commercial and office buildings are 347 V.
Alberta STANDATA 24-ECB-030 treats a double ended lamp luminaire on a ballast over 150 V to ground that is disconnected and reconnected as a new luminaire requiring disconnecting means, and extends that to energy conservation retrofits.
So in a 347 V building the honest recommendation is usually a complete certified LED fixture, which also sidesteps the retrofit kit certification problem in STANDATA 24-ECB-002 entirely.
Alberta STANDATA 24-ECB-030Alberta STANDATA 24-ECB-002CSA C22.2 No. 250.1The paths, on an office building
What each one does to your hum, your bill and your ceiling
| Path | A fixture | Load after, on 104 | What you actually notice |
|---|---|---|---|
| LED tube on the existing ballast | $105 to $135 | 7.3 kW | The hum stays, because the ballast stays. Saves the least. |
| LED tube, ballast removed | $179 to $215 | 6.2 kW | Hum gone, nothing left to fail. Restricted at 347 V. |
| New LED panel, one for one | $241 to $275 | 4.2 to 5.7 kW | Best light quality, biggest cut, and the right answer on 347 V. |
| Daylight harvesting near the glazing | Quoted per job | A further cut on what is left | The row of fixtures beside the windows running at full output at noon in June is money burning.PNNL-21923 lighting control field study |
The parts nobody quotes
Three real costs that show up on my quote and not on the low bid
Proof, and what is not in it
Example buildings, real fixture counts, real prices
Two example buildings, drawn at the fixture count I quote
104 fixtures, an example Edmonton shop
94 fixtures, an example dealership showroom
Every square is one fixture. Example buildings at the counts and prices I actually quote, not round numbers.
Dmitry Naboka, Master Electrician #13824, 14 years in the trade. Co owner Kyle V., Journeyman. Five person crew, no subcontractors. Raydn Renewables has been trading since August 2025.
Who is actually on your roof and in your ceilingWhat the low bid leaves out on an office
Five things that are true, cost you money, and are missing from almost every office lighting quote
There is no LED rebate in Alberta right now
Energy Efficiency Alberta was wound up in 2020. The Emissions Reduction Alberta Energy Savings for Business program is closed and fully allocated. SEMI is industrial only. If a competitor payback calculation has a rebate line in it, that payback is made up. My calculator has no rebate field, and that is deliberate.
ERA Energy Savings for Business program overviewERA Energy Savings for Business FAQEnergyRates.ca on the wound up Alberta business programThe write off is real, though
Commercial lighting normally lands in capital cost allowance Class 8 at 20 percent declining balance, and Class 8 qualifies for the accelerated first year allowance through 2027. Talk to your accountant about that, not to me. I am an electrician.
CRA capital cost allowance classesThe 347 volt trap, and why the cheap swap stops being cheap
Alberta STANDATA 24-ECB-030 says a luminaire with double ended lamps on a ballast rated over 150 volts to ground, disconnected and reconnected, counts as a new luminaire and needs disconnecting means. It extends that to energy conservation retrofits. Most Alberta warehouses and commercial buildings are 347 volt. So the cheap ballast bypass lands inside that sentence. A new fixture with no double ended lamps does not.
Alberta STANDATA 24-ECB-030Field modifying a certified fixture voids its certification
A proper retrofit uses a certified retrofit product and a new label on every single fixture, per CSA C22.2 No. 250.1, and the retrofit kit has to be certified for the fixture it goes into per STANDATA 24-ECB-002. I price the label. Most low bids do not, and the building owner inherits that at insurance or resale time.
CSA C22.2 No. 250.1Alberta STANDATA 24-ECB-002The row of fixtures beside the windows is burning money at noon in June
Daylight harvesting on the glazing row cuts what is left after the retrofit, not what you started with. It is quoted per job because it depends on your glazing and your ceiling, and most office quotes never mention it exists.
Straight answers
What I get asked on offices and commercial interiors
Should I use 4000 K or 5000 K in an office?
4000 K. 5000 K belongs in warehouses, shops and yards where you want contrast and alertness. In a room where people sit at a desk all day, 5000 K reads as clinical. Whatever you pick, use the same one everywhere including the fixtures you add later.
Will an LED retrofit stop the buzzing in my ceiling?
Only if the ballast comes out. The hum is the ballast. Putting an LED tube on top of the existing ballast, which is the cheapest option, leaves the buzzing exactly where it was.
My building is 347 V. What changes?
Alberta STANDATA 24-ECB-030
treats a double ended lamp luminaire on a ballast over 150 V to ground that is disconnected and reconnected as a new luminaire needing disconnecting means
And it extends that
to energy conservation retrofits
In practice
that pushes a 347 V office toward complete certified LED fixtures rather than a tube retrofit
And that also sidesteps the retrofit kit certification problem in STANDATA 24-ECB-002.
Can you do the work after hours?
Yes, and in an office that is usually the right call. We work zone by zone. A 100 fixture retrofit is normally two to four days with the five person crew.
Next step
Book the walkdown
Free. About an hour.You get a written scope with the option prices side by side.
What I measure while I am there
- 1
I count the fixtures
- 2
I meter one
- 3
I listen for ballast hum room by room
- 4
I confirm your supply voltage
- 5
I check what the ceiling grid will take before I show up
In an office the complaint list matters more than the fixture count, so bring it.
Booked. I have your number.
I will call you within 24 hours to set the time. If you want it sooner, call or text me at (780) 904-3462.
I do the walkdown myself. I meter a fixture, count what is actually up there, read your municipal lighting bylaw before I show up, and hand you a written scope with the option prices side by side. No pressure, and no rebate that does not exist.
Dmitry Naboka, Master Electrician #13824, 14 years in the trade