LED savings calculator

Most lighting quotes give you one savings number. I will give you the range, and show you every number behind it.

Pick what is up there now, how many, and how long they run.

Published wattage tables for the old fixtures

Real prices, the same ones I put on a quote

No rebate field, because Alberta does not have a rebate

Dmitry Naboka, Master Electrician #13824, 14 years in the trade.

5.0 on Google · 70+ verified reviews

What business customers say

Nobody has left us a review on a lighting retrofit yet, so I am not going to show you one. These two are real, from a business customer and a repeat electrical customer.

★★★★★
“Raydn Renewables is an amazing company. Their attitude and attention to detail as well as their quality of service stands out above every electrical and solar company we've worked with in the entire Alberta area. It's been a pleasure working with Raydn for their professionalism, organization and politeness. Look forward to working with them soon again in the future.”
Balance Roofing · Verified Google review
★★★★★
“I highly recommend Dima for any electrical work! He's professional, knowledgeable, and goes above and beyond to make sure the job is done right. Whether it's solar, EV charger installs, or other electrical needs, Dima takes the time to explain everything clearly and deliver top-quality work. He's reliable, efficient, and someone you can really trust to take care of your home or business. If you're looking for great service and peace of mind, Dima is the guy to call!”
Trevor Redmond · Verified Google review

Swipe sideways for 1 more →

Read all 70+ reviews →

Why a range

The four numbers that move the answer, and the one everybody gets wrong

20.0 kWdown to 5.2 kWAn example Edmonton shop, 104 old fluorescent fixtures. That is the connected lighting load before and after at my prices, not a brochure claim.
$0in Alberta LED rebatesThere is no program to apply to. The calculator has no rebate field because putting one in would be a lie that makes my number look better.
64 to 77%of rated lumensWhat metal halide actually holds in service. Probe start keeps about 64 percent of its initial rating, pulse start about 77. I size the LED against that, not the sticker.
2,000 lmis the Sherwood Park triggerStrathcona County requires full cutoff optics on any fixture rated 2,000 lumens or more, and the bylaw names retrofits specifically. Every commercial wall pack clears that.

The one people get wrong is the power rate. The energy line on your bill is not what a kilowatt hour costs you.

The energy line on your bill
What it actually costs delivered
18 to 22¢

The difference is these four

Distribution

Transmission

Rate riders

Municipal franchise fee

A calculator using the 8 cent number tells you the retrofit takes three times longer to pay back than it does. This one defaults to 20 cents and lets you drag it.

The four options

The cheapest option is not the one I recommend, and I will tell you why in writing

The four ways this gets done, on a 104 fixture four lamp shop at 3,650 hours and 20 cents delivered. Prices are installed, all in.
OptionLoad afterPer fixtureThe catch
Tube on the existing ballast7.3 kW$105 to $135 The ballast stays in and keeps drawing. It is also still the part most likely to fail. Saves the least.
Tube, ballast removed6.2 kW$179 to $215 More labour up front. Nothing left in the fixture to fail. Usually the right answer.
New fixture, one for one4.2 to 5.7 kW$241 to $275 Best light quality and the biggest cut. Costs the most and the old fixtures go in the bin.
Fewer high bays6.0 kW on 40 fixtures$490 to $540 Only works over 18 ft of ceiling. Under that you get dark aisles between the fixtures. Can raise your bill on small fixtures.

I price four options on the same 104 fixtures, from $11,443 to $26,242. All four go on one page with the load and the payback beside each, and the middle one is usually the right answer. That is the point of showing all four.

Dmitry Naboka, Master Electrician #13824

What other quotes leave out

Five things that are true, cost money, and are missing from most lighting quotes

There is no rebate to apply for

Energy Efficiency Alberta wound up in 2020. The Emissions Reduction Alberta Energy Savings for Business program is fully allocated. SEMI is industrial only. What is real is the capital cost allowance, Class 8 at 20 percent, which your accountant claims, not me.

ERA Energy Savings for Business program overview ERA Energy Savings for Business FAQ CRA capital cost allowance classes EnergyRates.ca on the wound up Alberta business program

HID to LED needs a permit

It is an improvement to the installation, not maintenance. In Edmonton a stand alone electrical permit runs $160 on a job up to $3,000 and $405 from $10,001 to $50,000, plus a 4 percent Safety Codes Levy. Those are the fees effective January 1, 2026.

City of Edmonton commercial electrical permits Edmonton 2026 Planning and Development Fee Schedules, Appendix D

Your municipality may force a more expensive fixture

Your municipality may force a more expensive fixture. Four different answers inside an hour of Edmonton:

Sherwood Park and St. Albert

Full cutoff optics

Parkland County

Dark Sky compliant on anything needing a permit

Spruce Grove

Can ask for a photometric plan showing the 2 lux contour

Edmonton

None of the above

Full cutoff optics run about 19 percent more on the fixture.

Strathcona County Land Use Bylaw s.3.10 St. Albert Land Use Bylaw 18/2024 s.3.24 Parkland County Land Use Bylaw, consolidated Spruce Grove Land Use Bylaw C-824-12 Part 6 s.37 Edmonton Zoning Bylaw 20001 s.5.120

347 V is not the same fixture

Most Alberta commercial exterior is 347 V and a 347 V capable wall pack costs about 22 percent more. On tube retrofits, STANDATA 24-ECB-030 restricts double ended lamps at 347 V outright.

Alberta STANDATA 24-ECB-030 CSA C22.2 No. 250.1

The old ballasts might be hazardous waste

Ballasts made before 1980 can contain PCBs, which makes them Class 9 dangerous goods under UN2315. They go to Aevitas in Edmonton under EPEA approval 134-05-00 and the Certificate of Recycling goes in your turnover package. The Eco Station will not accept them from a business.

Environment and Climate Change Canada, PCB rules for electrical contractors Aevitas Edmonton, EPEA approval 134-05-00 Alberta PCB checklist Edmonton Eco Station accepted items and fees

Straight answers

The questions I get asked on every walkdown

Why does the calculator give me a range instead of one number?

Because until I meter one of your fixtures I do not know where inside the wattage band it sits. A four lamp T8 draws 110 W on a normal ballast factor and 132 W on a high one. Same fixture, same tubes, 20 percent apart. A single number would mean I picked one and hid the guess. The range is the honest version, and it narrows to a number on the walkdown.

Is there an LED rebate in Alberta?

No. Energy Efficiency Alberta was wound up in 2020. The Emissions Reduction Alberta Energy Savings for Business program is fully allocated and closed to new applications. SEMI is industrial only. Anyone quoting you a rebate on a commercial LED retrofit in Alberta right now is either working off old information or hoping you do not check. What is real is the capital cost allowance write off, Class 8 at 20 percent.

Does an LED retrofit need an electrical permit?

Going from HID or fluorescent to LED changes the installation, so yes, it takes a permit. Swapping a lamp for the same lamp is maintenance and does not. That distinction is where a lot of cheap lighting quotes live, and it is the customer who inherits the problem at resale or insurance time, not the installer.

Why is the ballast bypass option more expensive than leaving the ballast in?

Because somebody has to open every fixture, remove the ballast, rewire the sockets and relabel the fixture per CSA C22.2 No. 250.1. That is labour. Leaving the ballast in is faster and cheaper on day one, and then the ballast keeps drawing power and stays the part most likely to fail. I will install either one. I just will not pretend they are the same product.

My building is 347 V. Does that matter?

It matters a lot, and most Alberta commercial buildings are 347 V. Alberta STANDATA 24-ECB-030 restricts double ended LED lamp retrofits at 347 V. If somebody quotes you a Type B tube retrofit on a 347 V system without mentioning that bulletin, they have not read it.

What happens to the old tubes and ballasts?

Tubes have mercury and ballasts made before 1980 in Canada can contain PCBs. PCB ballasts are Class 9 dangerous goods, UN2315. They go to Aevitas in Edmonton under EPEA approval 134-05-00 and you get the Certificate of Recycling in your turnover package. The Eco Station will take tubes at a dollar each and will not take PCB ballasts from a business at all.

By building type

The same calculator, with the parts that only matter on your kind of building

Every one of these pages carries the wattage tables, the code notes and the price bands for that building type, plus the questions I actually get asked on it.

Next step

Book the walkdown

Free. About an hour.You get a written scope with the option prices side by side.

What I measure while I am there

  • 1

    I count the fixtures

  • 2

    I meter one

  • 3

    I meter the load you have now

  • 4

    I confirm your supply voltage

  • 5

    I hand you a written scope with the option prices side by side

The calculator gives you a range. The walkdown is what turns it into a number I will stand behind.

Book it

Two fields to send it. I call you back myself, within 24 hours.

What kind of building?

Or call me directly, (780) 904-3462. No sales visit, no subcontractor. The Master Electrician who quotes it is the one who does it.

I do the walkdown myself. I meter a fixture, count what is actually up there, read your municipal lighting bylaw before I show up, and hand you a written scope with the option prices side by side. No pressure, and no rebate that does not exist.

Dmitry Naboka, Master Electrician #13824, 14 years in the trade
Honest quote in 24 hours